<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Tracer Wire &#8211; Reid Terra</title>
	<atom:link href="https://www.reidterra.com/product-category/pro-line/utility-marking-products/tracer-wire/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.reidterra.com</link>
	<description></description>
	<lastBuildDate>Sat, 14 Jul 2018 23:13:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.3</generator>
<site xmlns="com-wordpress:feed-additions:1">185428055</site>	<item>
		<title>PRO-TRACE HF-CCS PE45</title>
		<link>https://www.reidterra.com/product/pro-trace-hf-ccs-pe45/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:55:37 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=309</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION PRO-TRACE HF-CCS PE45 tracer wire is designed to have the flexibility, memory, and feel of copper.  It also has a 43% higher break-load , minimizing damage during installation and while in service.  This product is best suited for open-trench,  applications.  Equal in signal tracing performance, it simply outperforms copper tracer wire and significantly [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2"><strong>APPLICATIONS &amp; INFORMATION</strong></h3>
<div>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE45</strong> tracer wire is designed to have the flexibility, memory, and feel of copper.  It also has a 43% higher break-load , minimizing damage during installation and while in service.  This product is best suited for open-trench,  applications.  Equal in signal tracing performance, it simply outperforms copper tracer wire and significantly reduces material costs.</span></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li><span style="color: #000000;">Designed for Open-Cut, Plow-In, and Blow-In Applications.</span></li>
<li><span style="color: #000000;">Flexibility, Memory, and Feel of Copper.</span></li>
<li><span style="color: #000000;">43% Higher Breakload than Copper.</span></li>
<li><span style="color: #000000;">Corrosion Resistant Properties of Copper</span></li>
<li><span style="color: #000000;">Tracer Wire Performance Equal to Copper.</span></li>
<li><span style="color: #000000;">45 Mil, High-Density, HMWPE Insulation, and Direct Burial Rated.</span></li>
<li><span style="color: #000000;">Significantly Lower in Cost with Great Price Stability.</span></li>
<li><span style="color: #000000;">User-Friendly and Virtually No &#8220;Recoil&#8221;.</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div></div>
<div class="descrip">
<h3 class="hdng2"><strong>STANDARDS &amp; REFERENCES</strong></h3>
<div>
<div><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE45</strong> conductor meets or exceeds all applicable ASTM specifications, and requirements of the National Electrical Code.</span></div>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>
<div><span style="color: #000000;">ASTM B910 / B190M: Standard Specification for Annealed Copper-Clad Steel Wire.</span></div>
</li>
<li><span style="color: #000000;">ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper.</span></li>
<li><span style="color: #000000;">ASTM D1248: Standard Standard Specification for Polyethylene Plastics Extrusion Materials For Wire and Cable</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<div></div>
<h3 class="hdng2">TRACER WIRE CONSTRUCTION</h3>
<div>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE45</strong> is a flexible, copper-clad steel tracer wire. A low carbon steel core, metallurgically bonded with a copper cladding, that is uniform and continuous, creating a bi-metal conductor that acts as one and is corrosion resistant. Special annealing processes are performed during the cladding process giving HF-CCS the flexibility and feel of copper, but 43% higher in strength which means less breaks then copper tracer wire.</span></p>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE45</strong> uses a thicker, 45 mil, high-density, high molecular weight polyethylene (HDPE) insulation for extra protection. HDPE provides an excellent balance of surface smoothness, processing ease and electrical consistency. HDPE provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</span></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 1: CONDUCTOR PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE45%20TRACER%20WIRE/TABLE%201%20-%20CONDUCTOR%20PROPERTIES.jpg" alt="" width="690" height="197" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 2: INSULATION PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE45%20TRACER%20WIRE/TABLE%202%20-%20INSULATION%20PROPERTIES.jpg" alt="" width="690" height="274" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE45%20TRACER%20WIRE/WEIGHTS,%20MEASUREMENTS,%20AND%20PACKAGING.jpg" alt="" width="690" height="455" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">SPECIFICATION EXAMPLE (FOR SPECIFYING ENGINEERS)</div>
<div>
<p><span lang="EN"><span style="color: #000000;">Tracer wire for open-cut installation shall be a 12 AWG solid, PRO-TRACE HF-CCS PE45.  Conductor shall be annealed, 21% IACS, copper-clad steel, utilizing a AISI 1006 low carbon steel core with minimum break load of 282 lbs or 55,000 psi (required to meet break load, flexbility, and ASTM B910).  Conductor shall be extruded with a 45 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HF-CCS PE45 as manufactured by Pro-Line Safety Products.</span></span></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">309</post-id>	</item>
		<item>
		<title>PRO-TRACE HF-CCS PE30</title>
		<link>https://www.reidterra.com/product/pro-trace-hf-ccs-pe30/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:54:57 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=308</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION PRO-TRACE HF-CCS PE30 tracer wire is designed to have the flexibility, memory, and feel of copper.  It also has a 43% higher break-load , minimizing damage during installation and while in service.  This product is best suited for open-trench applications.  Equal in signal tracing performance, it simply outperforms copper tracer wire and significantly [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2">APPLICATIONS &amp; INFORMATION</h3>
<div>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE30</strong> tracer wire is designed to have the flexibility, memory, and feel of copper.  It also has a 43% higher break-load , minimizing damage during installation and while in service.  This product is best suited for open-trench applications.  Equal in signal tracing performance, it simply outperforms copper tracer wire and significantly reduces material costs.</span></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li><span style="color: #000000;">Designed for Open-Cut, Plow-In, and Blow-In Applications.</span></li>
<li><span style="color: #000000;">Flexibility, Memory, and Feel of Copper.</span></li>
<li><span style="color: #000000;">43% Higher Break Load than Copper.</span></li>
<li><span style="color: #000000;">Corrosion Resistant Properties of Copper</span></li>
<li><span style="color: #000000;">Tracer Wire Performance Equal to Copper.</span></li>
<li><span style="color: #000000;">30 Mil, High-Density, HMWPE Insulation (HDPE), and Direct Burial Rated.</span></li>
<li><span style="color: #000000;">Significantly Lower in Cost with Great Price Stability.</span></li>
<li><span style="color: #000000;">User-Friendly and Virtually No &#8220;Recoil&#8221;.</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS &amp; REFERENCES</h3>
<div>
<div><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE30</strong> conductor meets or exceeds all applicable ASTM specifications, and requirements of the National Electrical Code.</span></div>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>
<div><span style="color: #000000;">ASTM B910 / B190M: Standard Specification for Annealed Copper-Clad Steel Wire.</span></div>
</li>
<li><span style="color: #000000;">ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper.</span></li>
<li><span style="color: #000000;">ASTM D1248: Standard Standard Specification for Polyethylene Plastics Extrusion Materials For Wire and Cable</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">TRACER WIRE CONSTRUCTION</h3>
<div>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE30</strong> is a flexible, copper-clad steel tracer wire. A low carbon steel core, metallurgically bonded with a copper cladding, that is uniform and continuous, creating a bi-metal conductor that acts as one and is corrosion resistant. Special annealing processes are performed during the cladding process giving HF-CCS the flexibility and feel of copper, but 43% higher in strength which means less breaks then copper tracer wire.</span></p>
<p><span style="color: #000000;"><strong>PRO-TRACE HF-CCS PE30</strong> uses a 30 mil, high-density, high molecular weight polyethylene (HDPE) insulation. HDPE provides an excellent balance of surface smoothness, processing ease and electrical consistency. HDPE provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</span></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 1: CONDUCTOR PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE30%20TRACER%20WIRE/TABLE%201%20-%20CONDUCTOR%20PROPERTIES.jpg" alt="" width="690" height="197" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 2: INSULATION PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE30%20TRACER%20WIRE/TABLE%202%20-%20INSULATION%20PROPERTIES.jpg" alt="" width="690" height="274" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HF-CCS%20PE30%20TRACER%20WIRE/WEIGHTS,%20MEASUREMENTS,%20AND%20PACKAGING.jpg" alt="" width="690" height="455" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">SPECIFICATION EXAMPLE (FOR SPECIFYING ENGINEERS)</div>
<div>
<p><span style="color: #000000;">Tracer wire for open-cut installation shall be a 12 AWG solid, PRO-TRACE HF-CCS PE30.  Conductor shall be annealed, 21% IACS, copper-clad steel, utilizing a AISI 1006 low carbon steel core with minimum break load of 282 lbs or 55,000 psi (required to meet break load, flexbility, and ASTM B910).  Conductor shall be extruded with a 30 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HF-CCS PE30 as manufactured by Pro-Line Safety Products.</span></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">308</post-id>	</item>
		<item>
		<title>PRO-TRACE HDD-CCS PE45</title>
		<link>https://www.reidterra.com/product/pro-trace-hdd-ccs-pe45/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:53:43 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=292</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION (NEW &#38; IMPROVED) PRO-TRACE HDD-CCS PE45 tracer wire has almost 7X the break load of copper, which allows 1 wire to be installed in directional boring and pipe bursting applications .  This tracer wire provides the perfect balance between strength, ductility, and brittleness to ensure durability.  When copper tracer wire is used, 2 to 5 wires may [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<div class="hdng2">APPLICATIONS &amp; INFORMATION</div>
<div>
<p><span style="color: #000000;"><strong>(NEW &amp; IMPROVED) PRO-TRACE HDD-CCS PE45</strong> tracer wire has almost 7X the break load of copper, which allows 1 wire to be installed in directional boring and pipe bursting applications .  This tracer wire provides the perfect balance between strength, ductility, and brittleness to ensure durability.  When copper tracer wire is used, 2 to 5 wires may be used to obtain the needed strength to prevent breakage. In comparison, using 1 wire of 12, 10, or 8 AWG HDD-CCS is successful and costs substantially less.  Bottom line is PRO-TRACE HDD-CCS tracer wire is superior to copper in strength and durability.  Take a look at some of the advantages.</span></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li><span style="color: #000000;">Designed for directional boring<span style="color: #221e1f; font-size: small;"> or pipe bursting using 1 wire</span></span></li>
<li><span style="color: #000000;">Perfect Balance Between Tensile Strength, Ductility, and Brittleness</span></li>
<li><span style="color: #000000;">Has up to <strong>7X</strong> <strong>(or 700%)</strong> the break load of Copper</span></li>
<li><span style="color: #000000;">Corrosion Resistant Properties of Copper</span></li>
<li><span style="color: #000000;">Tracer Wire Performance Equal to Copper</span></li>
<li><span style="color: #000000;">High-Density, HMWPE Insulation, and Direct Burial Rated</span></li>
<li><span style="color: #000000;">Significantly Lower in Cost and Great Price Stability</span></li>
<li><span style="color: #000000;">Most Durable Tracer Wire on the Market</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<div class="hdng2">STANDARDS &amp; REFERENCES</div>
<div>
<div><span style="color: #000000;"><strong>PRO-TRACE HDD-CCS PE45</strong> conductor meets or exceeds all applicable ASTM specifications, and requirements of the National Electrical Code.</span></div>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>
<div><span style="color: #000000;">ASTM B910 / B190M: Standard Specification for Annealed Copper-Clad Steel Wire.</span></div>
</li>
<li><span style="color: #000000;">ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper.</span></li>
<li><span style="color: #000000;">ASTM D1248: Standard Standard Specification for Polyethylene Plastics Extrusion Materials For Wire and Cable</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<div class="hdng2">TRACER WIRE CONSTRUCTION</div>
<div>
<p><span style="color: #000000;"><strong>PRO-TRACE HDD-CCS PE45 </strong>is an extra high-strength, copper clad steel tracer wire.  A high carbon steel core, metallurgically bonded with a copper cladding, that is uniform and continuous, creating a bi-metal conductor that acts as one and is corrosion resistant.  The extreme break load allows only 1 conductor to be used in any tracer wire application for directional drilling (boring) or pipe bursting.  It provides the perfect balance between break load, ductility, and decreased brittleness.  It is the best performing tracer wire on the market for mechanical strength.</span></p>
<p><span style="color: #000000;"><strong>PRO-TRACE HDD-CCS PE45</strong> uses a thicker, 45 mil, high-density, high molecular weight polyethylene (HDPE) insulation for extra protection in demanding installs. HDPE provides an excellent balance of surface smoothness, processing ease and electrical consistency. HDPE provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</span></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 1: CONDUCTOR PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HD-CCS%20PE45%20TRACER%20WIRE/TABLE%201%20-%20CONDUCTOR%20PROPERTIES.jpg" alt="" width="690" height="197" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">TABLE 2: INSULATION PROPERTIES (PHYSICAL, MECHANICAL AND ELECTRICAL)</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HD-CCS%20PE45%20TRACER%20WIRE/TABLE%202%20-%20INSULATION%20PROPERTIES.jpg" alt="" width="690" height="273" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/PRO-TRACE%20HD-CCS%20PE45%20TRACER%20WIRE/WEIGHT,%20MEASUREMENTS,%20AND%20PACKAGING.jpg" alt="" width="690" height="381" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">SPECIFICATION EXAMPLE (FOR SPECIFYING ENGINEERS)</div>
<div>
<p><span lang="EN"><span style="color: #000000;">Tracer wire for directional boring installation shall be a <strong>14 AWG solid, PRO-TRACE HDD-CCS PE45</strong>.  Conductor shall be hard-drawn, 21% IACS, copper-clad steel, utilizing a AISI 1065 high carbon steel core with minimum break load of 855 lbs or 265,000 psi (required to meet break load).  Conductor shall be extruded with a 45 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HDD-CCS PE45 as manufactured by Pro-Line Safety Products.</span></span></p>
<p><span style="color: #000000;">Tracer wire for directional boring installation shall be a <strong>12 AWG solid, PRO-TRACE HDD-CCS PE45</strong>.  Conductor shall be hard-drawn, 21% IACS, copper-clad steel, utilizing a AISI 1055 high carbon steel core with minimum break load of 1,330 lbs or 260,000 psi (required to meet break load).  Conductor shall be extruded with a 45 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HDD-CCS PE45 as manufactured by Pro-Line Safety Products.</span></p>
<p><span lang="EN"><span style="color: #000000;">Tracer wire for directional boring installation shall be a <strong>10 AWG solid, PRO-TRACE HDD-CCS PE45</strong>.  Conductor shall be hard-drawn, 21% IACS, copper-clad steel, utilizing a AISI 1055 high carbon steel core with minimum break load of 1,940 lbs or 238,000 psi (required to meet break load).  Conductor shall be extruded with a 45 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HDD-CCS PE45 as manufactured by Pro-Line Safety Products.</span></span></p>
<p><span lang="EN"><span style="color: #000000;">Tracer wire for directional boring installation shall be a <strong>8 AWG solid, PRO-TRACE HDD-CCS PE45</strong>.  Conductor shall be hard-drawn, 21% IACS, copper-clad steel, utilizing a AISI 1065 high carbon steel core with minimum break load of 2,785 lbs or 215,000 psi (required to meet break load).  Conductor shall be extruded with a 45 mil, high density, high molecular weight polyethylene (HMW-HDPE) persuant to ASTM D1248.  Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant.  Tracer wire shall be PRO-TRACE HDD-CCS PE45 as manufactured by Pro-Line Safety Products.</span></span></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">292</post-id>	</item>
		<item>
		<title>CU TFN &#038; TFFN</title>
		<link>https://www.reidterra.com/product/cu-tfn-tffn/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:52:39 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=291</guid>

					<description><![CDATA[APPLICATIONS TFN or TFFN Tracer Wire is primarily used in low voltage applications up to 600 volts for locating buried gas, water, sewer, electric and telephone lines in comercial, industrial or residential applications. When used as type TFN or TFFN, conductor is suitable for use in dry locations at temperatures not to exceed 90°C. Voltage rating for TFN or TFFN applications is 600 volts. SPECIFICATIONS [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<div><strong>TFN</strong> or <strong>TFFN Tracer Wire</strong> is primarily used in low voltage applications up to 600 volts for locating buried gas, water, sewer, electric and telephone lines in comercial, industrial or residential applications. When used as type <strong>TFN</strong> or <strong>TFFN</strong>, conductor is suitable for use in dry locations at temperatures not to exceed 90°C. Voltage rating for <strong>TFN</strong> or <strong>TFFN</strong> applications is 600 volts.</div>
</div>
</div>
<div class="descrip">
<div class="hdng2">SPECIFICATIONS</div>
<div>
<div>Pro-Line Type <strong>TFN</strong> or <strong>TFFN</strong> <strong>Tracer Wire</strong> meets or exceeds all applicable ASTM specifications, UL Standard 66 and requirements of the National Electrical Code.</div>
</div>
</div>
<div class="descrip">
<div class="hdng2">CONSTRUCTION</div>
<div>
<p>&nbsp;</p>
<p><span style="color: #000000;"><strong>Conductor</strong></span></p>
<p><strong>TFN</strong> or <strong>TFFN Tracer Wire</strong> is composed of a dead soft annealed copper conductor. Copper conductors utilize a UNS C10200 grade copper that is oxygen free and is drawn down from copper rod.</p>
<div></div>
<div><strong><span style="color: #000000;">Insulation</span></strong></div>
<p>The insulation material is a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-Listed equal jacket is applied. Available in black, white, red, blue, green, yellow, brown, orange, and gray.</p>
<div></div>
<div><span style="color: #000000;"><strong>Print</strong></span></div>
<div>Insulation print applied to the insulation surface to repeat at a minimum interval of every foot. Ink color will include black ink for yellow, blue, green, red, orange and green insulation, and white ink for black insulation.</div>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/TFN-TFFN%20Tracer%20Wire%20Chart%20(Web%20Pic).jpg" alt="" width="689" height="457" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2"><strong>RECOMMENDED TRACER WIRE SPECIFICATIONS</strong></div>
<div>
<div>Tracer wire shall be UL Listed, Type TFN (or &#8220;TFFN&#8221;), gasoline and oil resistant, and suitable for operations at 600 volts as specified in the National Electric Code. Conductor size shall be a 16 AWG solid copper conductor (or &#8220;16 AWG 26-Strand copper conductor&#8221;). Conductor shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent. Tracer wire shall be manufactured on 500’ non-returnable plastic spools. Tracer wire shall be Pro-Line Safety Products Company.</div>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">291</post-id>	</item>
		<item>
		<title>COPPER UF</title>
		<link>https://www.reidterra.com/product/copper-uf/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:51:25 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=290</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION Pro-Line Type CU UF conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets. When used as Type CU UF, conductor is suitable for use direct burial applications not locations at temperatures [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>APPLICATIONS &amp; INFORMATION<br />
Pro-Line Type CU UF conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets.</p>
<p>When used as Type CU UF, conductor is suitable for use direct burial applications not locations at temperatures not to exceed -20°C or 60°C.</p>
<p>Considered as the premium grade copper tracer wire, it offers the best protection with a thick PVC insulation.</p>
<p>Tracer wire is RoHS Compliant and manufacturered in the USA.<br />
STANDARDS &amp; REFERENCES<br />
Pro-Line Type CU UF conductors meets or exceeds all applicable ASTM specifications, UL Standards 493, Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
<p>ASTM B-3: Standard Specification for Soft or Annealed Copper Wire<br />
ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper<br />
CONSTRUCTION<br />
Pro-Line Type CU UF copper conductors are annealed copper (soft drawn), insulated with a polyvinyl chloride (PVC) insulation. PVC provides an excellent balance of surface smoothness, processing ease and electrical consistency. PVC provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</p>
<p>Available in black, blue, green, orange, purple, red, white, and yellow. Some colors standard, some subject to economic order quantity.</p>
<p>WEIGHTS, MEASUREMENTS, AND PACKAGING</p>
<p>CU UF TRACER WIRE (FOR SPECIFYING ENGINEERS)<br />
Tracer wire shall be a (14, 12 or 10 AWG SOLID), Type UF, copper conductor with a polyvinyl chloride (PVC) insulation and rated for 600 volts. Insulation shall be RoHS compliant and utilize virgin grade material. Insulation color shall meet the APWA color code standard for identification of buried utilities. Tracer wire shall be Pro-Line Safety Products or approved equal and made in the USA.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">290</post-id>	</item>
		<item>
		<title>COPPER THHN</title>
		<link>https://www.reidterra.com/product/copper-thhn/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:50:50 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=289</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION Pro-Line Type THHN or THWN conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets. When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2">APPLICATIONS &amp; INFORMATION</h3>
<div>
<ul>
<li>Pro-Line <strong>Type THHN</strong> or <strong>THWN</strong> conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets.</li>
<li>When used as <strong>Type THHN</strong>, conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as <strong>Type THWN</strong>, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant.</li>
<li>When used as <strong>Type MTW</strong>, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60°C or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79). When used as <strong>Type</strong> <strong>AWM</strong>, conductor temperatures not to exceed 105°C in dry locations.</li>
<li>Tracer wire is RoHS Compliant and manufacturered in the USA.</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS &amp; REFERENCES</h3>
<div>
<p>Pro-Line <strong>Type THHN</strong> or <strong>THWN</strong> or <strong>MTW</strong> (also <strong>AWM</strong>) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line <strong>Type THHN</strong> or <strong>THWN</strong> or <strong>MTW</strong> copper conductors are annealed copper (soft drawn), insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied.</li>
<li>Available in black, blue, brown, gray, green, orange, pink, purple, red, white, and yellow. Some colors standard, some subject to economic order quantity.</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20THHN%20TRACER%20WIRE%20(TABLES).jpg" alt="" width="690" height="848" /></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CU THHN TRACER WIRE (FOR SPECIFYING ENGINEERS)</h3>
<div>
<p><span style="color: #000000;">Tracer wire shall be a (14, 12 or 10 AWG SOLID THHN) copper conductor with a polyvinyl chloride (PVC) insulation, over which a nylon (polyamide) jacket is applied and rated for 600 volts. Insulation and jacket shall be RoHS compliant and utilize virgin grade material. Insulation color shall meet the APWA color code standard for identification of buried utilities. Tracer wire shall be Pro-Line Safety Products or approved equal and made in the USA</span></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">289</post-id>	</item>
		<item>
		<title>COPPER PE45</title>
		<link>https://www.reidterra.com/product/copper-pe45/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:49:03 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=293</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION Pro-Line Type CU HDPE 45 MIL conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets. When used as Type CU HDPE 45 MIL, conductor is suitable for use direct burial applications not locations at [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2">APPLICATIONS &amp; INFORMATION</h3>
<div>
<ul>
<li>Pro-Line <strong>Type CU HDPE 45 MIL</strong> conductors are used for tracer wire applications not exceeding 600 Volts. Tracer wire is used to conductively locate buried utility lines for the gas, water, sewer, telecommunication, and electrical markets.</li>
<li>When used as <strong>Type CU HDPE 45 MIL</strong>, conductor is suitable for use direct burial applications not locations at temperatures not to exceed 75°C.</li>
<li>Tracer wire is RoHS Compliant and manufacturered in the USA.</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">STANDARDS &amp; REFERENCES</h3>
<div>
<p>Pro-Line <strong>Type CU HDPE 45 MIL</strong> conductors meets or exceeds all applicable ASTM specifications, requirements of the National Electrical Code.</p>
<ul>
<li>ASTM B-3: Standard Specification for Soft or Annealed Copper Wire</li>
<li>ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper</li>
<li>ASTM D1248: Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable</li>
<li>ASTM D1238: Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line <strong>Type CU HDPE 45 MIL</strong> copper conductors are annealed copper (soft drawn), insulated with a high-density, high molecular weight polyethylene (HDPE) insulation. HDPE provides an excellent balance of surface smoothness, processing ease and electrical consistency. HDPE provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</li>
<li>Available in black, blue, green, orange, purple, red, white, and yellow. Some colors standard, some subject to economic order quantity.</li>
</ul>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20HDPE%2045%20MIL%20TRACER%20WIRE%20(TABLES).jpg" alt="" width="690" height="828" /></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CU HDPE 45 MIL TRACER WIRE (FOR SPECIFYING ENGINEERS)</h3>
<div>
<p><span style="color: #000000;">Tracer wire shall be a (14, 12 or 10 AWG SOLID HDPE 45 MIL) copper conductor with a 45 mil thick, high-density, high molecular weight polyethylene (HDPE) insulation and rated for 600 volts. Insulation and jacket shall be RoHS compliant and utilize virgin grade material. Insulation color shall meet the APWA color code standard for identification of buried utilities. Tracer wire shall be Pro-Line Safety Products or approved equal and made in the USA.</span></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">293</post-id>	</item>
		<item>
		<title>COPPER PE30</title>
		<link>https://www.reidterra.com/product/288/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 22:44:19 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=288</guid>

					<description><![CDATA[APPLICATIONS &#38; INFORMATION Pro-Line Type CU HDPE 30 MIL is a solid, copper tracer wire designed for applications not exceeding 30 volts.  Tracer wire is used to conductively located buried utility lines for the gas, water, sewer, telecom and electrical markets.   This wire may also be used for underground pet fence systems.  100% Copper Conductor. [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="descrip">
<h3 class="hdng2">APPLICATIONS &amp; INFORMATION</h3>
<div>
<p><span style="color: #000000;"><strong>Pro-Line Type CU HDPE 30 MIL </strong>is a solid, copper tracer wire designed for applications not exceeding 30 volts.  Tracer wire is used to conductively located buried utility lines for the gas, water, sewer, telecom and electrical markets.   This wire may also be used for underground pet fence systems. </span></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li><span style="color: #000000;">100% Copper Conductor.</span></li>
<li><span style="color: #000000;">Corrosion Resistant</span></li>
<li><span style="color: #000000;">30 Mil, High-Density, HMWPE Insulation, and Direct Burial Rated.</span></li>
<li><span style="color: #000000;">RoHS Compliant, Direct Burial Rated, 30 Volts.</span></li>
<li><span style="color: #000000;">Moisture, Chemical, and Oil Resistant</span></li>
<li><span style="color: #000000;">Impact, Crush, and Abrasion Resistant</span></li>
<li><span style="color: #000000;">User-Friendly and Flexible with No &#8220;Recoil&#8221;.</span></li>
<li><span style="color: #000000;">Made in the USA</span></li>
</ul>
</li>
</ul>
</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS &amp; REFERENCES</h3>
<div>
<p>Pro-Line <strong>Type CU HDPE 30 MIL</strong> conductors meets or exceeds all applicable ASTM specifications, requirements of the National Electrical Code.</p>
<ul>
<li>ASTM B-3: Standard Specification for Soft or Annealed Copper Wire</li>
<li>ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper</li>
<li>ASTM D1248: Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable</li>
<li>ASTM D1238: Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line <strong>Type CU HDPE 30 MIL</strong> copper conductors are annealed copper (soft drawn), insulated with a high-density, high molecular weight polyethylene (HDPE) insulation. HDPE provides an excellent balance of surface smoothness, processing ease and electrical consistency. HDPE provides superior strength against underground elements that help prevent accidental breaks caused buy rocks in shifting soil conditions.</li>
<li>Available in black, blue, green, orange, purple, red, white, and yellow. Some colors standard, some subject to economic order quantity.</li>
</ul>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS, AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20HDPE%2030%20MIL%20TRACER%20WIRE%20(TABLES).jpg" alt="" width="690" height="828" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">CU HDPE 30 MIL TRACER WIRE (FOR SPECIFYING ENGINEERS)</div>
<div>
<p><span style="color: #000000;">Tracer wire shall be a (14, 12 or 10 AWG SOLID HDPE 30 MIL) copper conductor with a 30 mil thick, high-density, high molecular weight polyethylene (HDPE) insulation and rated for 30 volts. Insulation and jacket shall be RoHS compliant and utilize virgin grade material. Insulation color shall meet the APWA color code standard for identification of buried utilities. Tracer wire shall be Pro-Line Safety Products or approved equal and made in the USA.</span></p>