<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Control &amp; Power Cable &#8211; Reid Terra</title>
	<atom:link href="https://www.reidterra.com/product-category/pro-line/wire-cable/control-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.reidterra.com</link>
	<description></description>
	<lastBuildDate>Mon, 16 Jul 2018 15:51:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.3</generator>
<site xmlns="com-wordpress:feed-additions:1">185428055</site>	<item>
		<title>XHHW / PVC POWER CABLE</title>
		<link>https://www.reidterra.com/product/xhhw-pvc-power-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:39:45 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=436</guid>

					<description><![CDATA[600 Volts Copper Conductors XLP Insulated Singles Rated XHHW (or XLPTC) Non-Shielded Tray Cable Available in 3 or 4 Conductors with Ground Overall PVC Jacket Flame Retardant, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings Primary installations include cable trays, [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>XLP Insulated Singles Rated XHHW (or XLPTC)</li>
<li>Non-Shielded Tray Cable</li>
<li>Available in 3 or 4 Conductors with Ground</li>
<li>Overall PVC Jacket</li>
<li>Flame Retardant, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>This cable may be used in wet or dry locations at temperatures not to exceed 90°C. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC 336.10</li>
</ul>
<p>&nbsp;</p>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Power Cable meets or exceeds the applicable requirements of the</div>
<div>following standards and specifications:</div>
<ul>
<li>ASTM &#8211; (All applicable standards)</li>
<li>UL 1277 &#8211; Electrical Power and Control Tray Cables</li>
<li>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 4 &#8211; single color (black) compounds with surface printing of numbers)</div>
</li>
</ul>
<ul>
<li>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 Btu/hr)</li>
<li>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</li>
</ul>
<p>Pro-Line’s Type TC Power Cable meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) &#8211; Nonshielded 0 &#8211; 2 kV Cables, with testing frequencies based on UL requirements.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Power Cable is available in sizes 8 AWG through 750 kcmil and is manufactured using Type XHHW-2 conductors. Individual conductors are bare annealed copper covered with a cross-linked polyethylene (XLP) insulation. The overall jacket consists of a flame retardant, moisture and sunlight resistant PVC jacket. TC Power Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<ul>
<li>Sizes 8 thru 2 AWG: Concentric, compressed or compact stranding, class B (7 strands) per ASTM B-8</li>
<li>Sizes 1 thru 4/0 AWG: Concentric, compressed or compact stranding, class B (19 strands) per ASTM B-8</li>
<li>Sizes 250 thru 500 KCMIL: Concentric, compressed or compact stranding, class B (37 strands) per ASTM B-8</li>
<li>Size 750 KCMIL: Concentric, compressed or compact stranding, class B (61 strands) per ASTM B-8</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/Type%20TC%20POWER%20CABLE%20XHHW%20(Cut%20Sheet).jpg" alt="" width="690" height="695" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">436</post-id>	</item>
		<item>
		<title>XHHW / PVC CONTROL CABLE</title>
		<link>https://www.reidterra.com/product/xhhw-pvc-control-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:38:05 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=435</guid>

					<description><![CDATA[600 Volts Copper Conductors FR-XLP Insulated Singles Type XHHW Rated VW-1 Overall PVC Jacket Heat, Moisture and Sunlight-Resistant APPLICATIONS &#160; Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>FR-XLP Insulated Singles Type XHHW</li>
<li>Rated VW-1</li>
<li>Overall PVC Jacket</li>
<li>Heat, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<p>&nbsp;</p>
<ul>
<li>Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Control Cable is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>Conductors may be used in wet or dry locations at temperatures not to exceed 90°C</li>
</ul>
<p>&nbsp;</p>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Control Cable meets or exceeds the applicable requirements of the</div>
<div>following standards and specifications:</div>
<div></div>
<ul>
<li>
<div>ASTM &#8211; (All applicable standards)</div>
</li>
<li>
<div>UL 1277 &#8211; Electrical Power and Control Tray Cables</div>
</li>
<li>
<div>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</div>
</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</div>
</li>
<li>
<div>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</div>
</li>
<li>
<div>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</div>
</li>
</ul>
<div></div>
<div>Type TC Control Cable meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) &#8211; Nonshielded 0 &#8211; 2kV Cables, with testing frequencies based on UL requirements.</div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<div>Pro-Line’s Type TC Control Cable is available in sizes 14 AWG through 10 AWG, with multi-conductor constructions of 2 through 37 conductors. The product uses Type XHHW-2 rated VW-1conductors. Individual conductors are bare annealed copper covered with a cross-linked polyethylene (XLP). The overall jacket consists of a flame retardant, moisture, and sunlight-resistant PVC. TC Control Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20XHHW%20PVC%20TC%20CONTROL%20(Cut%20Sheet).jpg" alt="" width="690" height="993" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">435</post-id>	</item>
		<item>
		<title>THHN / PVC POWER CABLE</title>
		<link>https://www.reidterra.com/product/thhn-pvc-power-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:36:20 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=434</guid>

					<description><![CDATA[600 Volts Copper Conductors PVC/Nylon Insulated Singles Rated THHN (or VNTC) Non-Shielded Tray Cable Available in 3 or 4 Conductors with Ground Overall PVC Jacket Flame Retardant, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings Primary installations include [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>PVC/Nylon Insulated Singles Rated THHN (or VNTC)</li>
<li>Non-Shielded Tray Cable</li>
<li>Available in 3 or 4 Conductors with Ground</li>
<li>Overall PVC Jacket</li>
<li>Flame Retardant, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>This cable may be used at temperatures not to exceed 75°C in wet locations and 90°C in dry locations. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC 336.10</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Power Cable meets or exceeds the applicable requirements of the</div>
<p>following standards and specifications:</p>
<ul>
<li>ASTM &#8211; (All applicable standards)</li>
<li>UL 1277 &#8211; Electrical Power and Control Tray Cables</li>
<li>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</li>
<li>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</li>
<li>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</li>
<li>ICEA T-30-250 &#8211; Vertical Cable Tray Flame Test (70,000 BTU/hr)</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</li>
<li>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Power Cable is available in sizes 8 AWG through 750 kcmil and is manufactured using Type THHN or THWN conductors. Individual conductors are bare annealed copper covered with a polyvinyl chloride (PVC) insulation over which a nylon (polyamide) or UL listed equal jacket is applied. The overall jacket consists of a flame retardant, moisture and sunlight resistant PVC jacket. TC Power Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<ul>
<li>Sizes 8 thru 2 AWG: Concentric, compressed or compact stranding, class B (7 strands) per ASTM B-8 or 19 wire combination stranding per ASTM B-787</li>
<li>Sizes 1 thru 4/0 AWG: Concentric, compressed or compact stranding, class B (19 strands) per ASTM B-8 or 19 wire combination stranding per ASTM B-787</li>
<li>Sizes 250 thru 500 KCMIL: Concentric, compressed or compact stranding, class B (37 strands) per ASTM B-8</li>
<li>Size 750 KCMIL: Concentric, compressed or compact stranding, class B (61 strands) per ASTM B-8</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/Type%20TC%20POWER%20CABLE%20THHN%20(Cut%20Sheet).jpg" alt="" width="690" height="757" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">434</post-id>	</item>
		<item>
		<title>THHN / PVC CONTROL CABLE</title>
		<link>https://www.reidterra.com/product/thhn-pvc-control-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:34:05 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=433</guid>

					<description><![CDATA[600 Volts Copper Conductors PVC / Nylon Insulated Singles Type THHN Sizes 16 Through 10 AWG Overall PVC Jacket Heat, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired Primary installations include cable trays, raceways, and outdoor locations [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>PVC / Nylon Insulated Singles Type THHN</li>
<li>Sizes 16 Through 10 AWG</li>
<li>Overall PVC Jacket</li>
<li>Heat, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Control Cable meets or exceeds the applicable requirements of the following standards and specifications:</div>
<ul>
<li>
<div>ASTM &#8211; (All applicable standards)</div>
</li>
<li>
<div>UL 1277 &#8211; Electrical Power and Control Tray Cables</div>
</li>
<li>
<div>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</div>
</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</div>
</li>
<li>
<div>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-30-250 &#8211; Vertical Cable Tray Flame Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</div>
</li>
<li>
<div>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</div>
</li>
</ul>
<div></div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Control Cable is available in sizes 16 AWG through 10 AWG, with multi-conductor constructions of 2 through 37 conductors. The product uses Type THHN or THWN conductors in sizes 14 AWG through 10 AWG. Individual conductors are bare annealed copper covered with a polyvinyl chloride (PVC) insulation over which a nylon (polyamide) or UL listed equal jacket is applied. The overall jacket consists of a heat, moisture and sunlight-resistant PVC. TC Control Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20THHN%20PVC%20TC%20CONTROL%20(Cut%20Sheet).jpg" alt="" width="690" height="993" /></p>
</div>