<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Copper Conductors &#8211; Reid Terra</title>
	<atom:link href="https://www.reidterra.com/product-category/pro-line/wire-cable/copper-conductors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.reidterra.com</link>
	<description></description>
	<lastBuildDate>Sat, 14 Jul 2018 23:25:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.3</generator>
<site xmlns="com-wordpress:feed-additions:1">185428055</site>	<item>
		<title>XHHW-2</title>
		<link>https://www.reidterra.com/product/xhhw-2/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:25:08 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=338</guid>

					<description><![CDATA[&#160; 600 Volts Copper Conductor Cross-Linked Polyethylene Insulation (XLP) High-Heat and Moisture Resistant Sizes 14 Through 8 AWG Also Rated SIS Black Sizes 2 AWG and Larger Sunlight-Resistant &#160; APPLICATIONS Pro-Line Type XHHW-2 conductors are primarily used in conduit or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>
<div>600 Volts</div>
</li>
<li>
<div>Copper Conductor</div>
</li>
<li>
<div>Cross-Linked Polyethylene Insulation (XLP)</div>
</li>
<li>
<div>High-Heat and Moisture Resistant</div>
</li>
<li>
<div>Sizes 14 Through 8 AWG Also Rated SIS</div>
</li>
<li>
<div>Black Sizes 2 AWG and Larger Sunlight-Resistant</div>
</li>
</ul>
<p>&nbsp;</p>
<div class="descrip">
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line Type XHHW-2 conductors are primarily used in conduit or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code.</li>
<li>XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C</li>
<li>Voltage rating for XHHW-2 conductors is 600 volts</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line Type XHHW-2 conductors meet or exceed UL Standard 44, Federal Specification A-A-59544, and requirements of the National Electrical Code. Type XHHW-2 meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) &#8211; Nonshielded 0 &#8211; 2 kV Cables, with testing frequencies based on UL requirements.</p>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line Type XHHW-2 copper conductors are annealed (soft) copper. Insulation is an abrasion, moisture, and heat resistant cross-linked polyethylene (XLP)</li>
<li>Sizes 14, 12, and 10 AWG available in black, white, red, blue, yellow, green, orange, brown, purple, and gray</li>
<li>Conductor sizes 2 AWG and larger listed and marked sunlight resistant in black only</li>
</ul>
<blockquote dir="ltr">
<div></div>
<div><strong><span style="color: #000000;">ALTERNATE CONSTRUCTION</span></strong></div>
</blockquote>
<ul>
<li>Pro-Line Type XHHW-2 copper conductors are also available in sizes 1/0 AWG and larger rated for cable tray use and sunlight resistant</li>
<li>Specify XHHW-2 for CT use when requesting quote or ordering</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p align="left"><strong><span style="font-size: medium;"><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20XHHW%20(Cut%20Sheet).jpg" alt="" width="690" height="944" /></span></strong></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">RECOMMENDED SPECIFICATIONS</div>
<div>
<div><strong><span style="color: #000000;">RECOMMENDED SAMPLE SPECIFICATIONS</span></strong></div>
<p>Conductors shall be UL-listed Type XHHW-2, suitable for operation at 600 volts or less in wet or dry locations, at temperatures not to exceed 90°C. Conductors shall be annealed copper. XHHW-2 shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<div></div>
<div></div>
<div></div>
<div><strong><span style="color: #000000;">CABLE TRAY RELATED RECOMMENDED SAMPLE SPECIFICATIONS</span></strong></div>
<div>Conductor shall be UL-listed Type XHHW-2 rated for cable tray use and sunlight resistance. Also, suitable for operation at 600 volts or less in wet or dry locations, at temperatures not to exceed 90°C. Conductors shall be annealed copper. XHHW-2 shall be PRO-LINE WIRE &amp; CABLE or approved equal.</div>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">338</post-id>	</item>
		<item>
		<title>UF-B</title>
		<link>https://www.reidterra.com/product/uf-b/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:24:22 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=337</guid>

					<description><![CDATA[&#160; 600 Volts Copper Conductor Sunlight, Moisture, and Fungus Resistant Overall Thermoplastic Insulation (PVC) &#160; APPLICATIONS Pro-Line Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code UF-B cable may be [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>600 Volts</li>
<li>
<div>Copper Conductor</div>
</li>
<li>
<div>Sunlight, Moisture, and Fungus Resistant</div>
</li>
<li>
<div>Overall Thermoplastic Insulation (PVC)</div>
</li>
</ul>
<p>&nbsp;</p>
<div class="descrip">
<div class="hdng2"><strong>APPLICATIONS</strong></div>
<div>
<ul>
<li>Pro-Line Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code</li>
<li>UF-B cable may be used underground, including direct burial</li>
<li>Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code</li>
<li>UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<div class="hdng2"><strong>STANDARDS AND REFERENCES</strong></div>
<div>
<p>Pro-Line Type UF-B cable meets or exceeds UL Standard 83, UL Standard 493, Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line Type UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire</li>
<li>Copper conductors are annealed (soft) copper, solid or compressed stranded</li>
<li>Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes</li>
<li>Jacketed with sunlight, moisture and fungus resistant gray PVC</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20UF-B%20(Cut%20Sheet).jpg" alt="" width="690" height="660" /></p>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">337</post-id>	</item>
		<item>
		<title>THHN THWN-2 MTW AWM</title>
		<link>https://www.reidterra.com/product/thhn-thwn-2-mtw-awm/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:23:44 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=336</guid>

					<description><![CDATA[&#160; 600 Volts Copper Conductor Thermoplastic Insulation / Nylon Sheath Heat, Moisture, Gasoline, and Oil Resistant Sizes AWG and Larger Rated THWN-2 All Stranded Sizes Rated MTW and THWN Sizes 14 Through 6 AWG Rated AWM (105°C) Sizes 14 Through 1 AWG Rated VW-1 Size 1/0 AWG and Larger Listed for CT Use Black Size [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>600 Volts</li>
<li>
<div>Copper Conductor</div>
</li>
<li>
<div>Thermoplastic Insulation / Nylon Sheath</div>
</li>
<li>
<div>Heat, Moisture, Gasoline, and Oil Resistant</div>
</li>
<li>
<div>Sizes AWG and Larger Rated THWN-2</div>
</li>
<li>
<div>All Stranded Sizes Rated MTW and THWN</div>
</li>
<li>
<div>Sizes 14 Through 6 AWG Rated AWM (105°C)</div>
</li>
<li>
<div>Sizes 14 Through 1 AWG Rated VW-1</div>
</li>
<li>
<div>Size 1/0 AWG and Larger Listed for CT Use</div>
</li>
<li>
<div>Black Size 2 AWG and Larger Listed Sunlight-Resistant</div>
</li>
</ul>
<p>&nbsp;</p>
<div class="descrip">
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code.</li>
<li>When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90°C.</li>
<li>When used as Type THWN-2, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant.</li>
<li>When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60°C or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79).</li>
<li>Conductor temperatures not to exceed 105°C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts.</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line Type THHN or THWN-2 or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line Type THHN or THWN-2 or MTW copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-listed equal jacket is applied.</li>
<li>Available in black, white, red, blue, green, yellow, brown, orange, and gray; some colors standard, some subject to economic order quantity.</li>
<li>Conductor sizes 2 AWG and larger listed and marked sunlight-resistant in black only.</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20THHN%20(Cut%20Sheet).jpg" alt="" width="690" height="963" /></p>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">RECOMMENDED SPECIFICATIONS</h3>
<div>
<p><strong><span style="color: #000000;">MTW or THHN or THWN-2<br />
</span></strong>Conductors shall be UL-listed Type MTW or THHN or THWN-2 gasoline and oil resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. Sizes 14 through 1 AWG shall be rated VW-1, larger sizes shall be listed for CT use. Sizes 2 AWG and larger listed and marked sunlight-resistant in black only. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent. THHN shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<p><strong><span style="color: #000000;">AWM<br />
</span></strong>Conductors shall be UL-listed Type THHN or THWN-2 or MTW or AWM, suitable for operation at 600 volts at conductor temperatures not to exceed 105°C.</p>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">336</post-id>	</item>
		<item>
		<title>TFFN / TFN</title>
		<link>https://www.reidterra.com/product/tffn-tfn/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:22:52 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=335</guid>

					<description><![CDATA[&#160; 600 Volts Copper Conductor Thermoplastic Insulation / Nylon Sheath Heat, Moisture, Oil, and Gasoline Resistant Also Rated MTW and TEWN (CSA) 105°C AWM 18 and 16 AWG Solid Conductor Listed as TFN APPLICATIONS Pro-Line Type TFFN or TEWN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>600 Volts</li>
<li>Copper Conductor</li>
<li>Thermoplastic Insulation / Nylon Sheath</li>
<li>Heat, Moisture, Oil, and Gasoline Resistant</li>
<li>Also Rated MTW and TEWN (CSA) 105°C AWM</li>
<li>18 and 16 AWG Solid Conductor Listed as TFN</li>
</ul>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line Type TFFN or TEWN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code</li>
<li>When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90°C</li>
<li>When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60°C or dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)</li>
<li>Conductor temperatures not to exceed 105°C in dry locations when rated AWM and used as appliance wiring material type MTW of TEWN</li>
<li>Voltage for all applications is 600 volts</li>
</ul>
</div>
</div>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line Type TFFN or TEWN or MTW or AWM meets or exceeds UL Standard 66, CSA, and requirements of the National Electrical Code.</p>
</div>
</div>
<div class="descrip">
<div></div>
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<ul>
<li>Pro-Line Type TFFN or TEWN or MTW or AWM copper conductors are annealed (soft) copper, insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied</li>
<li>Available in black, white, red, blue, green, yellow, orange, brown, purple, gray, and pink; some colors standard, some subject to economic order quantity</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<div class="hdng2"><strong>WEIGHTS, MEASUREMENTS AND PACKAGING</strong></div>
<div>
<p align="center"><span style="font-size: medium;"><strong><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20TFFN%20TFN%20TEWN%20MTW%20(Cut%20Sheet).jpg" alt="" width="690" height="680" /></strong></span></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">RECOMMENDED SPECIFICATIONS</h3>
<div>
<div><strong><span style="color: #000000;">TFFN or TEWN or MTW or AWM</span></strong></div>
<p>Conductors shall be UL-listed Type TFFN or TEWN or MTW or AWM gasoline and oil resistant II, suitable for operation at 600 volts as specified in the National Electrical Code. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon. Type TFFN or TEWN or MTW or AWM shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<div><span style="color: #000000;"><strong>TFN</strong></span></div>
<div>Pro-Line Type TFN conductors may be used as fixture wire and as permitted for fire protective signal circuits as specified in the National Electrical Code at conductor temperatures not to exceed 90°C or 105°C when used as AWM. Voltage rating for all applications is 600 volts. Type TFN shall be PRO-LINE WIRE &amp; CABLE or approved equal.</div>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">335</post-id>	</item>
		<item>
		<title>RHH RHW-2 USE-2</title>
		<link>https://www.reidterra.com/product/rhh-rhw-2-use-2/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:22:07 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=334</guid>

					<description><![CDATA[&#160; 600 Volts Copper Conductors Underground Service Entrance Cable Cross-Linked Polyethylene Insulation (XLP) High-Heat, Moisture, and Sunlight-Resistant Sizes 6 Through 4/0 AWG Also Rated SIS APPLICATIONS Pro-Line Type RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the National Electrical Code When used as Type USE-2, conductor is suitable for use [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>Underground Service Entrance Cable</li>
<li>Cross-Linked Polyethylene Insulation (XLP)</li>
<li>High-Heat, Moisture, and Sunlight-Resistant</li>
<li>Sizes 6 Through 4/0 AWG Also Rated SIS</li>
</ul>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line Type RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the National Electrical Code</li>
<li>When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90°C</li>
<li>When used as RHH, conductor temperatures shall not exceed 90°C in dry locations</li>
<li>When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations</li>
<li>Voltage rating for RHH or RHW-2 or USE-2 conductors is 600 volts</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<div class="hdng2"><strong>STANDARDS AND REFERENCES</strong></div>
<div>
<p>Pro-Line Type RHH or RHW-2 or USE-2 meets or exceeds UL Standard 44 (for RHH or RHW-2), UL Standard 854 (for USE-2), Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
</div>
</div>
<div class="descrip">
<div></div>
<div class="hdng2"><strong>CONSTRUCTION</strong></div>
<div>
<ul>
<li>Pro-Line Type RHH or RHW-2 or USE-2 copper conductors are annealed (soft) copper</li>
<li>Insulation is an abrasion, moisture, heat, and sunlight resistant black cross-linked polyethylene (XLP)</li>
</ul>
</div>
</div>
<div class="descrip">
<div class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</div>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20RHH%20RHW%20USE%20(Cut%20Sheet).jpg" alt="" width="690" height="944" /></p>
</div>
</div>
<div class="descrip">
<div class="hdng2">RECOMMENDED SPECIFICATIONS</div>
<div>
<p>Conductors shall be UL-listed Type RHH or RHW-2 or USE-2, suitable for operation at 600 volts or less in wet or dry locations, including direct burial in the earth. Conductors shall be annealed copper, cross-linked polyethylene (XLP) insulated. Type RHH or RHW-2 or USE-2 shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">334</post-id>	</item>
		<item>
		<title>BARE COPPER WIRE</title>
		<link>https://www.reidterra.com/product/bare-copper-wire/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sat, 14 Jul 2018 23:18:14 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=333</guid>

					<description><![CDATA[APPLICATIONS Suitable for use as follows: Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook-up, jumpers, and grounds in electrical construction STANDARDS &#38; REFERENCES Pro-Line Bare Copper wire and cable meets or exceeds the [&#8230;]]]></description>
										<content:encoded><![CDATA[<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<p>Suitable for use as follows:</p>
<ul>
<li>Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications</li>
<li>Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook-up, jumpers, and grounds in electrical construction</li>
</ul>
</div>
</td>
</tr>
</tbody>
</table>
<div class="descrip">
<h3></h3>
<h3 class="hdng2">STANDARDS &amp; REFERENCES</h3>
<div>
<p><strong><em>Pro-Line</em></strong> Bare Copper wire and cable meets or exceeds the following ASTM specifications:</p>
<ul>
<li>B-1 Hard-Drawn Copper Wire</li>
<li>B-2 Medium-Hard Copper Wire</li>
<li>B-3 Soft or Annealed Copper Wire</li>
<li>B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft</li>
</ul>
</div>
</div>
<div class="descrip">
<div></div>
<div class="hdng2"><strong>CONSTRUCTION</strong></div>
<div>
<ul>
<li>Bare copper, solid or stranded</li>
<li>Available in tempers hard, medium-hard, or soft; stranded conductors are concentrically stranded</li>
</ul>
</div>
</div>
<div class="descrip">
<div>
<p align="center"><strong>WEIGHTS, MEASUREMENTS AND PACKAGING</strong></p>
</div>
<div class="center"><img src="http://www.prolinesafety.com/assets/item/descriptionimage/thumbnail/037-B-table.gif" alt="037-B-table.gif" /></div>