<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Products &#8211; Reid Terra</title>
	<atom:link href="https://www.reidterra.com/shop/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.reidterra.com</link>
	<description></description>
	<lastBuildDate>Mon, 16 Jul 2018 16:46:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.9.3</generator>
<site xmlns="com-wordpress:feed-additions:1">185428055</site>	<item>
		<title>Barricade Tape</title>
		<link>https://www.reidterra.com/product/barricade-tape-3/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Mon, 16 Jul 2018 16:45:08 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=359</guid>

					<description><![CDATA[Pro-Line Safety’s barricade tapes are great for marking off dangerous areas. Barricade tapes are made of safety yellow or danger red polyethylene. These above ground marking tapes are available in several mil thicknesses. &#160;]]></description>
										<content:encoded><![CDATA[<p>Pro-Line Safety’s barricade tapes are great for marking off dangerous areas. Barricade tapes are made of safety yellow or danger red polyethylene. These above ground marking tapes are available in several mil thicknesses.</p>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">359</post-id>	</item>
		<item>
		<title>MULTI-CONDUCTOR IRRIGATION CABLE</title>
		<link>https://www.reidterra.com/product/multi-conductor-irrigation-cable-2/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:46:29 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=439</guid>

					<description><![CDATA[30 Volts Solid Copper Conductor Polyvinyl Chloride (PVC) Insulated Singles Overall High Molecular Weight Polyethylene (PE) Jacket Nylon Rip Cord RoHS Compliant Direct Burial Rated APPLICATIONS Pro-Line’s Multi-Conductor Irrigation Cable is for use in direct burial applications for wiring of central control systems, field controls, and solenoid valves as specified in the National Electrical Code. Primary [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>30 Volts</li>
<li>Solid Copper Conductor</li>
<li>Polyvinyl Chloride (PVC) Insulated Singles</li>
<li>Overall High Molecular Weight Polyethylene (PE) Jacket</li>
<li>Nylon Rip Cord</li>
<li>RoHS Compliant</li>
<li>Direct Burial Rated</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Multi-Conductor Irrigation Cable is for use in direct burial applications for wiring of central control systems, field controls, and solenoid valves as specified in the National Electrical Code.</li>
<li>Primary installations include connection of solenoid valves with controllers on residential, electrically controlled irrigation systems</li>
<li>Multi-Conductor Irrigation Cable is listed for direct burial and may be used at temperatures not to exceed 60°C</li>
<li>Voltage for all applications is 30 volts</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line’s Multi-Conductor Irrigation Cable meets or exceeds the applicable requirements of the following standards and specifications:</p>
<ul>
<li>ASTM &#8211; (All applicable standards)</li>
<li>VW-1 &#8211; Flame Test</li>
<li>FT1 &#8211; Flame Test</li>
<li>UL &#8211; Underground Golf Course Sprinkler System Cable</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Multi-Conductor Irrigation Cable is available in 18 AWG solid copper, with multi-conductor constructions of 2 through 25 conductors. The product uses polyvinyl chloride (PVC) insulated singles. The overall jacket consists of a high molecular weight polyethylene (PE) with a nylon rip cord.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/Multi-Conductor%20Irrigation%20Cable%20(Chart).jpg" alt="" width="690" height="538" /></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">RECOMMENDED SPECIFICATIONS</h3>
<div>
<p>Conductors shall be UL-Listed Multi-Conductor Irrigation Cable for underground golf course sprinkler systems with a direct burial rating. Conductos shall be suitable for operation at 30 volts as specified in the National Electrical Code. Conductors shall be annealed solid copper, insulated with PVC, and jacketed with PE. Multi-Conductor Irrigation Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">439</post-id>	</item>
		<item>
		<title>UL/CSA ORANGE WELDING CABLE</title>
		<link>https://www.reidterra.com/product/ulcsa-orange-welding-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:44:16 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=438</guid>

					<description><![CDATA[600 Volts Premium Grade (Extra Hard Usage) Stranded Copper Conductors Paper Tape Seperator Chlorinated Polyethylene (CPE) Orange Jacket Temperature Rating: -55°C to 90°C Oil, Ozone, and Weather Resistant Flame Retardant RoHS Compliant APPLICATIONS Pro-Line’s UL / CSA Orange Welding Cable is designed for use as arc welding leads from the secondary side of the power source, [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Premium Grade (Extra Hard Usage)</li>
<li>Stranded Copper Conductors</li>
<li>Paper Tape Seperator</li>
<li>Chlorinated Polyethylene (CPE) Orange Jacket</li>
<li>Temperature Rating: -55°C to 90°C</li>
<li>Oil, Ozone, and Weather Resistant</li>
<li>Flame Retardant</li>
<li>RoHS Compliant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s UL / CSA Orange Welding Cable is designed for use as arc welding leads from the secondary side of the power source, typical of welders and welding generators</li>
<li>Designed for welding cable use where resistance to cuts, tears and abrasion is required</li>
<li>Sizes 1/0 and larger for permanent wiring in conduit or tray where flexible power leads must be installed</li>
<li>Temperature Rating: -55°C to 90°C</li>
<li>Voltage for all applications is 600 volts</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line’s UL / CSA Orange Welding Cable meets or exceeds the applicable requirements of the following standards and specifications:</p>
<ul>
<li><strong><span style="color: #000000;">UL Listed</span> / <span style="color: #000000;">CSA Certified</span> / <span style="color: #000000;">MSHA Approved</span> / <span style="color: #000000;">RoHS Compliant</span></strong></li>
<li>ASTM B-3: Specification for Soft or Annealed Copper Wire</li>
<li>ASTM B-172: Specification for 34 AWG (Class M) Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors</li>
<li>ASTM D-4313: Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Crosslinked Chlorinated Polyethylene</li>
<li>Sizes 6 AWG and Larger Rated Type RHH or RHW (UL) 600V. Sizes 1/0 and Larger Rated for CT Use</li>
</ul>
<p><span style="color: #000000;"> </span></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s UL / CSA Orange Welding Cable is manufactured using annealed rope-stranded bare copper conductor. A paper tape separates the conductor from the Jacket. A premium-grade 90°C CPE orange jacket is extruded onto the cable.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/WELDING%20CABLE/UL-CSA%20ORANGE%20WELDING%20CABLE%20(Chart).jpg" alt="" width="690" height="712" /></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">RECOMMENDED SPECIFICATIONS</h3>
<div>
<p>Conductors shall be a UL / CSA Orange Welding Cable with a temperature rating between -55°C to 90°C. Conductors shall be suitable for operation at 600 volts. Conductors shall be annealed stranded copper (Class M), with a Chlorinated Polyethylene (CPE) Orange Jacket. The Conductor shall also be seperated from the jacket with a paper tape seperator. UL / CSA Orange Welding Cable shall be <strong><span style="color: #000000;">PRO-LINE WIRE &amp; CABLE</span></strong> or approved equal.</p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">438</post-id>	</item>
		<item>
		<title>NON-UL BLACK WELDING CABLE</title>
		<link>https://www.reidterra.com/product/non-ul-black-welding-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:42:23 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=437</guid>

					<description><![CDATA[600 Volts Stranded Copper Conductors Paper Tape Seperator Ethylene Propylene Diene Monomer (EPDM) Jacket Temperature Rating: -55°C to 105°C Flame Retardant, Oil Resistant RoHS Compliant APPLICATIONS Pro-Line’s Non-UL Black Welding Cable is designed for use as arc welding leads from the secondary side of the power source, typical of welders and welding generators Designed for [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Stranded Copper Conductors</li>
<li>Paper Tape Seperator</li>
<li>Ethylene Propylene Diene Monomer (EPDM) Jacket</li>
<li>Temperature Rating: -55°C to 105°C</li>
<li>Flame Retardant, Oil Resistant</li>
<li>RoHS Compliant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Non-UL Black Welding Cable is designed for use as arc welding leads from the secondary side of the power source, typical of welders and welding generators</li>
<li>Designed for welding cable use where resistance to cuts, tears and abrasion is required</li>
<li>Temperature Rating: -55°C to 105°C</li>
<li>Voltage for all applications is 600 volts</li>
</ul>
<p>&nbsp;</p>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<p>Pro-Line’s Non-UL Black Welding Cable meets or exceeds the applicable requirements of the following standards and specifications:</p>
<ul>
<li>ASTM B-3: Specification for Soft or Annealed Copper Wire</li>
<li>ASTM B-172: Specification for 30 AWG (Class K) Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors</li>
<li>ICEA S-75-381: Portable and Power Feeder Cables for Use in Mines and Similar Applications</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Non-UL Black Welding Cable is manufactured using annealed rope-stranded bare copper conductor. A paper tape separates the conductor from the Jacket. A premium-grade 105°C EPDM black jacket is extruded onto the cable. Red jacket is also available and subject to economic runs.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/WELDING%20CABLE/NON-UL%20BLACK%20WELDING%20CABLE%20(Chart).jpg" alt="" width="690" height="782" /></p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">RECOMMENDED SPECIFICATIONS</h3>
<div>
<p>Conductors shall be a Non-UL Welding Cable with a temperature rating between -55°C to 105°C. Conductos shall be suitable for operation at 600 volts. Conductors shall be annealed stranded copper (Class K), with a Ethylene Propylene Diene Monomer (EPDM) Jacket. The Conductor shall also be seperated from the jacket with a paper tape seperator. Non-UL Black Welding Cable shall be <strong><span style="color: #000000;">PRO-LINE WIRE &amp; CABLE</span></strong> or approved equal.</p>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">437</post-id>	</item>
		<item>
		<title>XHHW / PVC POWER CABLE</title>
		<link>https://www.reidterra.com/product/xhhw-pvc-power-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:39:45 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=436</guid>

					<description><![CDATA[600 Volts Copper Conductors XLP Insulated Singles Rated XHHW (or XLPTC) Non-Shielded Tray Cable Available in 3 or 4 Conductors with Ground Overall PVC Jacket Flame Retardant, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings Primary installations include cable trays, [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>XLP Insulated Singles Rated XHHW (or XLPTC)</li>
<li>Non-Shielded Tray Cable</li>
<li>Available in 3 or 4 Conductors with Ground</li>
<li>Overall PVC Jacket</li>
<li>Flame Retardant, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>This cable may be used in wet or dry locations at temperatures not to exceed 90°C. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC 336.10</li>
</ul>
<p>&nbsp;</p>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Power Cable meets or exceeds the applicable requirements of the</div>
<div>following standards and specifications:</div>
<ul>
<li>ASTM &#8211; (All applicable standards)</li>
<li>UL 1277 &#8211; Electrical Power and Control Tray Cables</li>
<li>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 4 &#8211; single color (black) compounds with surface printing of numbers)</div>
</li>
</ul>
<ul>
<li>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 Btu/hr)</li>
<li>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</li>
</ul>
<p>Pro-Line’s Type TC Power Cable meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) &#8211; Nonshielded 0 &#8211; 2 kV Cables, with testing frequencies based on UL requirements.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Power Cable is available in sizes 8 AWG through 750 kcmil and is manufactured using Type XHHW-2 conductors. Individual conductors are bare annealed copper covered with a cross-linked polyethylene (XLP) insulation. The overall jacket consists of a flame retardant, moisture and sunlight resistant PVC jacket. TC Power Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<ul>
<li>Sizes 8 thru 2 AWG: Concentric, compressed or compact stranding, class B (7 strands) per ASTM B-8</li>
<li>Sizes 1 thru 4/0 AWG: Concentric, compressed or compact stranding, class B (19 strands) per ASTM B-8</li>
<li>Sizes 250 thru 500 KCMIL: Concentric, compressed or compact stranding, class B (37 strands) per ASTM B-8</li>
<li>Size 750 KCMIL: Concentric, compressed or compact stranding, class B (61 strands) per ASTM B-8</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/Type%20TC%20POWER%20CABLE%20XHHW%20(Cut%20Sheet).jpg" alt="" width="690" height="695" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">436</post-id>	</item>
		<item>
		<title>XHHW / PVC CONTROL CABLE</title>
		<link>https://www.reidterra.com/product/xhhw-pvc-control-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:38:05 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=435</guid>

					<description><![CDATA[600 Volts Copper Conductors FR-XLP Insulated Singles Type XHHW Rated VW-1 Overall PVC Jacket Heat, Moisture and Sunlight-Resistant APPLICATIONS &#160; Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>FR-XLP Insulated Singles Type XHHW</li>
<li>Rated VW-1</li>
<li>Overall PVC Jacket</li>
<li>Heat, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<p>&nbsp;</p>
<ul>
<li>Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Control Cable is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>Conductors may be used in wet or dry locations at temperatures not to exceed 90°C</li>
</ul>
<p>&nbsp;</p>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Control Cable meets or exceeds the applicable requirements of the</div>
<div>following standards and specifications:</div>
<div></div>
<ul>
<li>
<div>ASTM &#8211; (All applicable standards)</div>
</li>
<li>
<div>UL 1277 &#8211; Electrical Power and Control Tray Cables</div>
</li>
<li>
<div>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</div>
</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</div>
</li>
<li>
<div>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</div>
</li>
<li>
<div>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</div>
</li>
</ul>
<div></div>
<div>Type TC Control Cable meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) &#8211; Nonshielded 0 &#8211; 2kV Cables, with testing frequencies based on UL requirements.</div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<div>Pro-Line’s Type TC Control Cable is available in sizes 14 AWG through 10 AWG, with multi-conductor constructions of 2 through 37 conductors. The product uses Type XHHW-2 rated VW-1conductors. Individual conductors are bare annealed copper covered with a cross-linked polyethylene (XLP). The overall jacket consists of a flame retardant, moisture, and sunlight-resistant PVC. TC Control Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20XHHW%20PVC%20TC%20CONTROL%20(Cut%20Sheet).jpg" alt="" width="690" height="993" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">435</post-id>	</item>
		<item>
		<title>THHN / PVC POWER CABLE</title>
		<link>https://www.reidterra.com/product/thhn-pvc-power-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:36:20 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=434</guid>

					<description><![CDATA[600 Volts Copper Conductors PVC/Nylon Insulated Singles Rated THHN (or VNTC) Non-Shielded Tray Cable Available in 3 or 4 Conductors with Ground Overall PVC Jacket Flame Retardant, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings Primary installations include [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>PVC/Nylon Insulated Singles Rated THHN (or VNTC)</li>
<li>Non-Shielded Tray Cable</li>
<li>Available in 3 or 4 Conductors with Ground</li>
<li>Overall PVC Jacket</li>
<li>Flame Retardant, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>This cable may be used at temperatures not to exceed 75°C in wet locations and 90°C in dry locations. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC 336.10</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Power Cable meets or exceeds the applicable requirements of the</div>
<p>following standards and specifications:</p>
<ul>
<li>ASTM &#8211; (All applicable standards)</li>
<li>UL 1277 &#8211; Electrical Power and Control Tray Cables</li>
<li>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</li>
<li>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</li>
<li>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</li>
<li>ICEA T-30-250 &#8211; Vertical Cable Tray Flame Test (70,000 BTU/hr)</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</li>
<li>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Power Cable is available in sizes 8 AWG through 750 kcmil and is manufactured using Type THHN or THWN conductors. Individual conductors are bare annealed copper covered with a polyvinyl chloride (PVC) insulation over which a nylon (polyamide) or UL listed equal jacket is applied. The overall jacket consists of a flame retardant, moisture and sunlight resistant PVC jacket. TC Power Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
<ul>
<li>Sizes 8 thru 2 AWG: Concentric, compressed or compact stranding, class B (7 strands) per ASTM B-8 or 19 wire combination stranding per ASTM B-787</li>
<li>Sizes 1 thru 4/0 AWG: Concentric, compressed or compact stranding, class B (19 strands) per ASTM B-8 or 19 wire combination stranding per ASTM B-787</li>
<li>Sizes 250 thru 500 KCMIL: Concentric, compressed or compact stranding, class B (37 strands) per ASTM B-8</li>
<li>Size 750 KCMIL: Concentric, compressed or compact stranding, class B (61 strands) per ASTM B-8</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/Type%20TC%20POWER%20CABLE%20THHN%20(Cut%20Sheet).jpg" alt="" width="690" height="757" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">434</post-id>	</item>
		<item>
		<title>THHN / PVC CONTROL CABLE</title>
		<link>https://www.reidterra.com/product/thhn-pvc-control-cable/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:34:05 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=433</guid>

					<description><![CDATA[600 Volts Copper Conductors PVC / Nylon Insulated Singles Type THHN Sizes 16 Through 10 AWG Overall PVC Jacket Heat, Moisture and Sunlight-Resistant APPLICATIONS Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired Primary installations include cable trays, raceways, and outdoor locations [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>600 Volts</li>
<li>Copper Conductors</li>
<li>PVC / Nylon Insulated Singles Type THHN</li>
<li>Sizes 16 Through 10 AWG</li>
<li>Overall PVC Jacket</li>
<li>Heat, Moisture and Sunlight-Resistant</li>
</ul>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<ul>
<li>Pro-Line’s Type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired</li>
<li>Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire</li>
<li>Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits</li>
<li>Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations</li>
</ul>
</div>
<div class="descrip">
<h3 class="hdng2">STANDARDS AND REFERENCES</h3>
<div>
<div>Pro-Line’s Type TC Control Cable meets or exceeds the applicable requirements of the following standards and specifications:</div>
<ul>
<li>
<div>ASTM &#8211; (All applicable standards)</div>
</li>
<li>
<div>UL 1277 &#8211; Electrical Power and Control Tray Cables</div>
</li>
<li>
<div>UL 1581 &#8211; Electrical Wires, Cables and Flexible Cords</div>
</li>
<li>
<div>ICEA S-58-679 &#8211; Control Cable Conductor Identification. (Method 1, Table 2 &#8211; colored compounds with tracer colors &#8211; excluding white and green)</div>
</li>
<li>
<div>UL 1685 &#8211; UL Flame Exposure Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-30-250 &#8211; Vertical Cable Tray Flame Test (70,000 BTU/hr)</div>
</li>
<li>
<div>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 BTU/hr)</div>
</li>
<li>
<div>IEEE 1202 &#8211; Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)</div>
</li>
</ul>
<div></div>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Pro-Line’s Type TC Control Cable is available in sizes 16 AWG through 10 AWG, with multi-conductor constructions of 2 through 37 conductors. The product uses Type THHN or THWN conductors in sizes 14 AWG through 10 AWG. Individual conductors are bare annealed copper covered with a polyvinyl chloride (PVC) insulation over which a nylon (polyamide) or UL listed equal jacket is applied. The overall jacket consists of a heat, moisture and sunlight-resistant PVC. TC Control Cable shall be PRO-LINE WIRE &amp; CABLE or approved equal.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">WEIGHTS, MEASUREMENTS AND PACKAGING</h3>
<div>
<p><img loading="lazy" src="http://www.prolinesafety.com/UserFiles/Image/CU%20THHN%20PVC%20TC%20CONTROL%20(Cut%20Sheet).jpg" alt="" width="690" height="993" /></p>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">433</post-id>	</item>
		<item>
		<title>5kV/8kV, 115 MIL EPR/PVC (133/100%), T/S, W/G, ALUMINUM ARMOR (3/C)</title>
		<link>https://www.reidterra.com/product/5kv8kv-115-mil-eprpvc-133100-ts-wg-aluminum-armor-3c/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:28:54 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=432</guid>

					<description><![CDATA[&#160; 5kVU or 8kV Type MV-105 or MC. 3 Copper Conductors. Thermosetting Conductor Shield. EPR Insulation. Thermosetting Insulation Shield. Tape Shield. Copper Ground Wire. Aluminum Armor. PVC Jacket. APPLICATIONS Southwire AL09ET Type MV-105 or MC Cable is for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs or continuous rigid cable supports. These [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<div>
<p>5kVU or 8kV Type MV-105 or MC. 3 Copper Conductors. Thermosetting Conductor Shield. EPR Insulation. Thermosetting Insulation Shield. Tape Shield. Copper Ground Wire. Aluminum Armor. PVC Jacket.</p>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<p>Southwire AL09ET Type MV-105 or MC Cable is for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs or continuous rigid cable supports. These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 133% (ungrounded system) insulation level, and 8,000V, 100% insulation level (grounded system).</p>
</div>
<div class="descrip">
<h3 class="hdng2">SPECIFICATIONS</h3>
<div>
<p>Southwire AL09ET Type MV-105 or MC Cable is manufactured and tested in accordance with the latest revisions of the following standards and specification:</p>
<p>&nbsp;</p>
<ul>
<li>UL 1072 &#8211; Medium Voltage Power Cables.</li>
<li>ICEA S-93-639 (NEMA WC 74) &#8211; 5-46 kV Shielded Power Cable for Use in the Transmission &amp; Distribution of Electric Energy.</li>
<li>IEEE 1202 &#8211; Flame Test (70,000 Btu/hr Vertical Tray Test).</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 Btu/hr).</li>
</ul>
<p>Southwire AL09ET Type MV-105 or MC Cable offers heavy duty construction and flexible EPR insulation. Alternate constructions available. For use in cable trays per NEC Article 392. SOLONON™ low smoke, non halogen polyolefin jackets and CPE jackets are available upon request.</p>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Southwire AL09ET Type MV-105 or MC Cable offers heavy duty construction and flexible EPR insulation. Alternate constructions available. For use in cable trays per NEC Article 392. SOLONON™ low smoke, non halogen polyolefin jackets and CPE jackets are available upon request.</p>
</div>
</div>
<div class="descrip">
<div>
<p align="center"><strong>AL09ET 3c, 5/8kV, 115mil EPR(133/100%), TS, GW, Alum</strong></p>
</div>
<div class="center"><img src="http://www.prolinesafety.com/assets/item/descriptionimage/thumbnail/115.jpg" alt="115.jpg" /></div>
<div><a href="http://www.prolinesafety.com/store/item.aspx?DepartmentId=64&amp;ItemId=20&amp;#"> </a></div>
</div>
<div class="descrip">
<div>
<p><strong>SCOPE:</strong> This specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, interlock armored, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 133% insulation level, and 8,000V, 100% insulation level.</p>
<p><strong>STANDARDS:</strong> The following standards shall form part of this specification: UL Standard 1072 for Medium Voltage Power Cable and ICEA S-93-639 (NEMA WC 74) 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. CONDUCTOR: The conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA .</p>
<p><strong>CONDUCTOR SHIELD:</strong> The conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.</p>
<p><strong>INSULATION:</strong> The insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The nominal thickness shall be 0.115&#8243;.</p>
<p><strong>INSULATION SHIELD:</strong> The insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as semi-conducting. Over this layer shall be applied a helically-wrapped 5-mil copper tape with 25% overlap. The method of phase identification will be similar to ICEA Method 3, using printed circuit numbers and colors (1-BLACK, 2-RED, 3-BLUE).</p>
<p><strong>GROUNDING CONDUCTOR:</strong> The ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.</p>
<p><strong>ASSEMBLY:</strong> The insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.</p>
<p><strong>ARMOR:</strong> A single strip of interlocked armor of aluminum shall be applied over the assembly.</p>
<p><strong>JACKET:</strong> The cable shall be covered with a yellow PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards. The jacket will be sunlight resistant and will meet the requirements of UL 1685 &#8211; UL Flame Exposure Test. Optional SOLONON low smoke, non halogen polyolefin jackets and CPE jackets are available upon request.</p>
<p><strong>IDENTIFICATION:</strong> Manufacturer&#8217;s identification shall be printed on the jacket.</p>
<p><strong>TESTS:</strong> Qualification tests shall be conducted in accordance with the requirements of AEIC.</p>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">432</post-id>	</item>
		<item>
		<title>15kV, 220 MIL EPR/PVC 133%, T/S, W/G, ALUMINUM ARMOR (3/C)</title>
		<link>https://www.reidterra.com/product/15kv-220-mil-eprpvc-133-ts-wg-aluminum-armor-3c/</link>
		
		<dc:creator><![CDATA[administrator]]></dc:creator>
		<pubDate>Sun, 15 Jul 2018 17:27:03 +0000</pubDate>
				<guid isPermaLink="false">https://reidterra.ryanjponto.com/?post_type=product&#038;p=431</guid>

					<description><![CDATA[15kVU Type MV-105 or MC. 3 Copper Conductors. Thermosetting Conductor Shield. EPR Insulation. Thermosetting Insulation Shield. Tape Shield. Copper Ground Wire. Aluminum Armor. PVC Jacket. APPLICATIONS Southwire AL13ET Type MV-105 or MC Cable is for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs or continuous rigid cable supports. These cables are capable [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>15kVU Type MV-105 or MC. 3 Copper Conductors. Thermosetting Conductor Shield. EPR Insulation. Thermosetting Insulation Shield. Tape Shield. Copper Ground Wire. Aluminum Armor. PVC Jacket.</p>
<h3 class="hdng2">APPLICATIONS</h3>
<div>
<p>Southwire AL13ET Type MV-105 or MC Cable is for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs or continuous rigid cable supports. These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 15,000V, 133% insulation level (ungrounded system).</p>
</div>
<div class="descrip">
<h3 class="hdng2">SPECIFICATIONS</h3>
<div>
<p>Southwire AL13ET Type MV-105 or MC Cable is manufactured and tested in accordance with the latest revisions of the following standards and specification:</p>
<ul>
<li>UL 1072 &#8211; Medium Voltage Power Cables.</li>
<li>ICEA S-93-639 (NEMA WC 74) &#8211; 5-46 kV Shielded Power Cable for Use in the Transmission &amp; Distribution of Electric Energy.</li>
<li>IEEE 1202 &#8211; Flame Test (70,000 Btu/hr Vertical Tray Test).</li>
<li>ICEA T-29-520 &#8211; Vertical Cable Tray Flame Test (210,000 Btu/hr).</li>
<li>Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirments of AEIC CS-8.</li>
</ul>
</div>
</div>
<div class="descrip">
<h3 class="hdng2">CONSTRUCTION</h3>
<div>
<p>Southwire AL13ET Type MV-105 or MC Cable offers heavy duty construction and flexible EPR insulation. Alternate constructions available. For use in cable trays per NEC Article 392. SOLONON™ low smoke, non halogen polyolefin jackets and CPE jackets are available upon request.</p>
</div>
</div>
<div class="descrip">
<div>
<p align="center"><strong>AL13ET 3c, 15kV, 220mil EPR(133%), TS, GW, Alum Interlocked</strong></p>
</div>
<div class="center"><img src="http://www.prolinesafety.com/assets/item/descriptionimage/thumbnail/220.jpg" alt="220.jpg" /></div>
<div><a href="http://www.prolinesafety.com/store/item.aspx?DepartmentId=64&amp;ItemId=21&amp;#"> </a></div>
</div>
<div class="descrip">
<div>
<p><strong>SCOPE:</strong> This specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, interlock armored, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, direct burial, concrete-encased installations, cable trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 15,000V, 133% insulation level (ungrounded system).</p>
<p><strong>STANDARDS:</strong> The following standards shall form part of this specification: UL Standard 1072 for Medium Voltage Power Cable and ICEA S-93-639 (NEMA WC 74) 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy.</p>
<p><strong>CONDUCTOR:</strong> The conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.</p>
<p><strong>CONDUCTOR SHIELD:</strong> The conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.</p>
<p><strong>INSULATION:</strong> The insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The nominal thickness shall be 0.220&#8243;.</p>
<p><strong>INSULATION SHIELD:</strong> The insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as semi-conducting. Over this layer shall be applied a helically-wrapped 5-mil copper tape with 25% overlap. The method of phase identification will be similar to ICEA Method 3, using printed circuit numbers and colors (1-BLACK, 2-RED, 3-BLUE).</p>
<p><strong>GROUNDING CONDUCTOR:</strong> The ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.</p>
<p><strong>ASSEMBLY:</strong> The insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.</p>
<p><strong>ARMOR:</strong> A single strip of interlocked armor of aluminum shall be applied over the assembly.</p>
<p><strong>JACKET:</strong> The cable shall be covered with a red PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards. The jacket will be sunlight resistant and will meet the requirements of UL 1685 &#8211; UL Flame Exposure Test. Optional SOLONON low smoke, non halogen polyolefin jackets and CPE jackets are available upon request.</p>
<p><strong>IDENTIFICATION:</strong> Manufacturer&#8217;s identification shall be printed on the jacket.</p>
<p><strong>TESTS:</strong> Qualification tests shall be conducted in accordance with the requirements of AEIC.</p>
</div>
</div>
]]></content:encoded>
					
		
		